5-1 Description of Key pad’s function on the control panel
No. of Upper Layers Counted:
Displays the number of completed upper layer wrapping cycles. Screen should be blank prior to
start of wrapping cycle. When wrapping cycle begins, for each completed upper layer wrapping
cycle the number increases by 1. When number of upper layers counted reaches the number of
upper layers set, the film-seat will start descending.
No. of Upper Layers Set:
Displays the number of wrapping cycles set for the upper layer.
Cycle Setting of Upper Layer:
Sets the number of upper layer wrapping cycles. Press “▲” once increases wrapping cycle by 1 and
press “▼” decreases wrapping cycle by 1. Wrapping cycle can be set to 9 as maximum, however
usually is set between 2-5 depending on different needs. Please note that wrapping cycle can not be
set to 0, as to lengthen the life span of the elevation motor.
No. of Lower Layers Counted:
Displays the number of completed lower layer wrapping cycles. Screen should be blank prior to
start of wrapping cycle. When wrapping cycle begins, for each completed lower layer wrapping
cycle the number increases by 1. When number of lower layers counted reaches the number of
lower layers set, the film-seat will start ascending.
No. of Lower Layers Set:
Displays the number of wrapping cycles set for the lower layer.
Cycle Setting of Lower Layer:
Sets the number of lower layer wrapping cycles. Press “▲” once increases wrapping cycle by 1 and
press “▼” decreases wrapping cycle by 1. Wrapping cycle can be set to 9 as maximum, however
usually is set between 2-5 depending on different needs.
Status Indication:
For detail, refer section
5-3.
Breakdown Indication:
For detail, refer section
5-4
.
Wrapping Function Control:
For detail, refer section
5-2
.