beautypg.com

Item, Type – Vestil SWA-60-AW User Manual

Page 31

background image

F:\Manual\SM-1517R-110V-100514

14.05.2010.

- 29 -

Item

designation

Description &

function

Manufacture

Type

Technical data

Complies with the

following standards

Marking of

conformity granted

MS Protected

inverters

and motors

Iskra MS25-20

Ue=750VAC
Icu=100KA
Ie=20A

EN60947-2
EN60947-4-1
EN60204-1

CE,UL,CSA

IVR1 Inverter,

controls

motor1’s speed

DELTA VFD007E11A Ue=115VAC

0.75KW

EN50178,
EN61800-3

CE,UL

IVR2 Inverter,

controls

motor2’s speed

DELTA VFD004E11A Ue=115VAC

0.40KW

EN50178,
EN61800-3

CE,UL

IVR3 Inverter,

controls

motor3’s speed

DELTA VFD004E11A Ue=115VAC

0.40KW

EN50178,
EN61800-3

CE,UL

FAN Heat

sink

PROFANTEC

P1082HST

Ue=115VAC 0.14A EN 61000-3-2

IEC 801-4

CE,UL

E-STOP Emergency

stop

T.E. ZA5BT4/

10

Ue=400VAC
Ith=10A

EN60947-1,EN60947-5-
1

CE,UL,CSA

F1

Fuse, Protected the
cutter of solenoid

DEMEX FM04L-B/1A Ue=250V

Ith=10A
FUSE=1A

CE 947.3

CE.UL

F2

Fuse, Protected the
cutter of solenoid

DEMEX FM04L-B/1A Ue=250V

Ith=10A
FUSE=1A

CE 947.3

CE,UL

F3

Fuse, Input ac
power to switching
power sp1,sp2

DEMEX FM04L-B/3A Ue=250V

Ith=10A
FUSE=3A

CE 947.3

CE,UL