beautypg.com

Matrix control connections, Db9 female connector – Staub Electronics B-500-MTRX-230-8X8 BINARY - HDMI 8X8 MATRIX SWITCH WITH HDMI AND HDBASET OUTPUTS User Manual

Page 11

background image

B-500-MTRX-230-8x8 Installation Manual

Pg. 11

www.snapav.com Support: 866.838.5052

LINK

LINK

PWR

LINK

LINK

LINK

LINK

LINK

LINK

Engineered in the USA

Manufactured in Taiwan

IR IN ALL IR OUT

Matrix IR

Control Input

7.7. Matrix Control Connections

All drivers, associated software and extra documentation is available on the B-500-MTRX-230-8X8 product page at

www.SnapAV.com under the Support Tab.

7.7.1. IR Control

The B-500-MTRX-230-8X8 can be controlled by IR from the front panel receiver or by

attaching a mono cable from the control system flasher output to the “System IR In” port

on the back of the matrix switcher. For the most reliable control, use the System IR In port.

The matrix switcher will also process commands received on IR Receiver inputs from

B-500-RX-230-IR in zones connected via HDBaseT. (See Section 7.10.2. IR Pass-Through from Rooms to Sources

on page 15 for an application example of this feature.)

Note: System IR Control and the front panel IR Receiver can be disabled when not in use by using the Configuration

Utility. See the Configuration Utility manual section, “Other Settings” for more information.

7.7.2. RS232 Control

To control the B-500-MTRX-230-8x8 with RS232, the devices must connect using the correct pin configuration for the

control system in use.

The matrix switcher receives control data on pin 2 (RxD – Data Receive) and transmits control data on pin 3 (TxD

- Data Transmit). The connection cable between the matrix switcher and the Automation System will need to be

configured so that pin 2 (RxD) on the switcher is connected to the control system TxD pin, and pin 3 (TxD) on the

switcher is connected to the control system RxD (Data Receive) pin. See the diagram below for details.

Configuration for control system serial ports can vary. Refer to the documentation for the system in use to ensure

proper connection and configuration.

Note: This port is also used to communicate with a PC when using the PC Configuration Utility. Refer to the

Configuration Utility manual for details.

7.7.3. Ethernet/IP Control

The B-500-MTRX-230-8x8 includes an Ethernet port that can be used to control the device using Telnet Protocol. This

port follows TIA 568 A/B standards; please refer to these standards when terminating cables.

To configure the matrix switcher for use with the driver, it will be necessary to connect the unit to a PC and access it

with the Matrix Configuration Utility. See the Configuration Utility manual and the IP driver documentation for complete

setup instructions.

B-500-MTRX-230-8x8 RS232 Port Configuration

LINK

LINK

PWR

LINK

LINK

LINK

LINK

LINK

LINK

Engineered in the USA

Manufactured in Taiwan

IR IN ALL IR OUT

DB9 Female Connector

RxD (Data Receive)
TxD (Data Transmit)
GND

Pin

Function

2

RxD (Data Receive)

3

TxD (Data Transmit)

5

Ground/Common