KB Electronics KBDF-48 User Manual
Page 62
62
Function Group 10: Communication Mode (DIDF Option Board Required)
Function
No. Description
Range/Code
Factory
Setting
User
Setting
10.00 * Assigned Comm. Station Number
1 – 247
30
10.01–10.03 Reserved
—
— —
10.04 Communications
Watchdog
Timer 0000:
Disabled
0001: Enabled
0000
10.05 Watchdog
Timeout
(Seconds)
0.50 – 2.00
0.50
10.06 Reserved
—
— —
0 0: Stop 1: Run
1 0: Forward 1: Reverse
2 0:
N/A
1: Fault Reset
3 0: Local 1: Remote
4 0: N/A 1: Preset Frequency 1
5 0: N/A 1: Preset Frequency 2
6 0: N/A 1: Preset Frequency 3
7 0: N/A 1: Preset Frequency 4
8 0: N/A 1: Preset Frequency 5
9 0: N/A 1: Preset Frequency 6
10 0: N/A 1: Preset Frequency 7
10.07 Operational
Command
11 – 15 Reserved —
—
0 0: Stop 1: Run
1 0: Forward 1: Reverse
2 0: Normal 1: Fault
3 0: Local 1: Remote
4 0: N/A 1: Preset Frequency 1
5 0: N/A 1: Preset Frequency 2
6 0: N/A 1: Preset Frequency 3
7 0: N/A 1: Preset Frequency 4
8 0: N/A 1: Preset Frequency 5
9 0: N/A 1: Preset Frequency 6
10 0: N/A 1: Preset Frequency 7
10.08 Drive
Status
11 – 15 Reserved
—
—
00
Normal Operation
01
Short Circuit Trip
02
Current Limit
03
Current Limit Trip
04
Undervoltage Trip
05
Recovered Undervoltage Trip
06
Overvoltage Trip
07
Recovered Overvoltage Trip
08
Stop Mode
09
Flash Error
10
External Fault Trip
11
IODF Error
12
Phase Loss Trip
13 – 15 Reserved
—
—
16
Watch Dog Trip
17
Unknown Error
18
Data Error
19
Key Error
20
Memory Module Error
21
On Board Memory Error
22
Communication Watchdog Trip
23
Keypad Stop
24
Image Revision Error
25
Image Blank Error
26
Image Checksum Error
27
Image HP Code Error
28
Over Temperature Trip
10.09
Drive Status Description
29
Recovered Over Temperature
10.10 ** Communications Error Count
—
—
—
10.11 ** Motor Voltage
—
—
—
10.12 ** Motor Current
—
—
—
10.13 ** Bus Voltage
—
—
—
10.14 ** Motor Frequency
—
—
—
10.15–10.18 Reserved
—
— —
*Functions which can only be changed while the drive is in the Stop Mode. **Read only.