KB Electronics KBDF-48 User Manual
Page 42
![background image](/manuals/350792/42/background.png)
42
8.4.5 ANALOG OUTPUT
An Analog Output is provided, which puts out a 0 – 5 Volt DC signal and will linearly follow the
parameter programmed in Analog Output 1 Mode (Function 5.14). It can be used to monitor
Output Frequency, Set Frequency, Motor Voltage, Bus Voltage, and Motor Current. See Figure
34, for connections and drive programming. See Figure 35, for Analog Output 1 Gain settings
(factory set to 100%).
FIGURE 34
ANALOG OUTPUT
CONNECTIONS AND DRIVE PROGRAMMING
*Factory setting.
FIGURE 35
ANALOG OUTPUT GAIN
Program Function
Setting
5.14: Analog Output 1 Mode
0000: Output Frequency*
0001: Set Frequency
0002: Motor Voltage
0003: Bus Voltage
0004: Motor Current
5.15: Analog Output 1 Gain (%)
0 – 200% (100%*)