beautypg.com

KB Electronics KBDF-48 User Manual

Page 21

background image

21

FIGURE 6

GENERAL CONNECTION DIAGRAM

1

2

2

3

Notes: 1. Multi-Function Input Terminals (MFIT 1 – 5 on TB1 of the drive) are factory set for
N.O. Contacts or NPN Transistors (J1 set to the "N.O. / NPN" position), which use the internal
power supply. For NPN Transistors, which use an external power supply (5 – 24 Volts DC), set
Jumper J1 to the "EXT" position. For PNP Transistor circuits, which use the internal power
supply or an external power supply (5 – 24 Volts DC), set Jumper J1 to the "PNP" position.
2. Multi-Function Output Relay Contact Ratings: 1 Amp at 30 Volts DC, 0.5 Amp at 125 Volts
AC, and 0.25 Amp at 250 Volts AC. 3. Multi-Function Input Terminals (MFIT 6 – 7 on TB1 of the
IODF) only accept N.O. Contacts or NPN Transistors (which use the internal power supply).