beautypg.com

4 user wiring and piping – IAI America IX-NNN8040 User Manual

Page 34

background image

26

5. Precautions for Use

5.4

User Wiring and Piping

The robot comes with standard cables and tubes that the user can use in a desired wiring/piping
configuration.

User connector specifications

Rated voltage

3.0 V

Permissible current

1.1 A

Conductor size and number of wires

AWG 26 (0.15 mm

2

), 25 wires

Other

Twisted-pair cable (1 to 24), shielded

Piping specifications

Normal service pressure

0.8 MPa

I 4 mm x I 2.5 mm, 2 pieces

Dimensions (outer diameter x inner
diameter) and number of tubes

I 6 mm x I 4 mm, 2 pieces

Working medium

Air

ALM (indicator) specifications

Rated voltage

24 VDC

Rated current

12 mA

Illumination color

Red LED

Shape of Y-terminal

Spacer for user part installation

User Connector
D-sub 25-pin
connector for user
wiring (socket),
fixing screw M2.6

ALM indicator

Spacer for user
part installation

BK SW
Brake-release
switch

Standard cable (5 m)

BK power cable (outside robot)

M cable (outside robot)

PG cable (outside robot)

Y-terminal at the end

To controller

Air tube
I 4 (black, white)
I 6 (red, yellow)

I 4, I 6 quick joint
(2 pcs. each)

U cable
(outside robot)

M4, depth 5

30 N or less

External force applied to the spacers must not
exceed 30 N in the axial direction or 2 N

˜m in

the rotating direction (for each spacer).

2 N

˜m or less

Quick joint
I 6 (red)

Quick joint
I 4 (black)

Quick joint
I 6 (yellow)

Quick joint
I 4 (white)

150 mm

5.

2

3.

2

2.6 5.9

I 7

10

This manual is related to the following products: