beautypg.com

IAI America RCP4W User Manual

Page 35

background image

2. Installation

29

(2) Mounting method 1 (When Utilizing the Tapped Holes)

Follow the table below for the torque to tighten the attachment screws.

Standard Type

Tightening Torque [N•m]

Actuator Type

Tapping

Diameter In the case that steel is used for the

bolt seating surface:

In the case that aluminum is used

for the bolt seating surface:

SA5C

M4

3.59

1.76

SA6C/SA7C

M5

7.27

3.42

Wall-hang Type • Ceiling Type

Tightening Torque [N•m]

Actuator Type

Tapping

Diameter In the case that steel is used for the

bolt seating surface:

In the case that aluminum is used

for the bolt seating surface:

SA5C/SA6C/SA7C

M5

7.27

3.42

Mounting screw

x

It is recommended to use high-tensile bolts with ISO-10.9 or more.

x

The length of thread engagement should be 1.8 times more than the nominal diameter.

Caution: Pay attention to the bolt length. If a bolt with inappropriate length is used, damage on

tapped holes or accident or failure due to insufficient strength on the actuator

attachment.