Caution in Handling

1. This actuator is not conducted hygienic treatment to apply to food.

Have an appropriate protection when using the product in an environment related to food that

requires the hygienic management so the actuator would not directly touch the food.

In case the actuator has touched the food, do not treat it as selling goods.

2. Do not attempt to establish the settings for the speed and

acceleration/deceleration above the allowable range.

An operation with speed and acceleration/deceleration beyond the allowable range may cause an

abnormal noise, vibration, malfunction or shortened life.

3. Set the allowable load moment within the allowable range.

An operation with the load beyond the allowable load moment may cause an abnormal noise,

vibration, malfunction or shortened life. If it is extreme, flaking may occur on the guide.

4. Set the overhang length within the allowable range.

Attaching a load with an overhang length above the allowable range may cause vibration and

abnormal noise.

5. If back and forth operations are performed repeatedly in short distance, it may

wear out the film of grease.

Continuous back and forth operation within a distance less than 30mm may cause wear of grease.

As a reference, have approximately 5 cycles of back and forth operation in a distance more than

50mm in every 5,000 to 10,000 cycles to regenerate the oil film. Keep using the actuator with the

grease worn out may cause malfunction. If it is extreme, flaking may occur on the guide.

6. Make sure to attach the actuator properly by following this instruction manual.

Using the product with the actuator not being certainly retained or affixed may cause abnormal

noise, vibration, malfunction or shorten the product life.

7. Ensure use of the product in the specified conditions, environments and ranges.

An operation out of the guarantee may cause a drop in performance or malfunction of the product.