Sa7c, Current limit value and pressing force – IAI America RCP4W User Manual
Page 23
1. Specifications Check
17
x
SA7C
Pressing Force [N]
Current Limit Value [%]
Ball Screw Lead
[mm]
20
30
40
50
60
70
8
96.5
144.8
193.1
241.4
289.6
337.9
16
46.3
69.4
92.5
115.6
138.8
161.9
0
50
100
150
200
250
300
350
400
0%
10%
20%
30%
40%
50%
60%
70%
80%
SA7C
Current Limit Value and Pressing Force
Current Limit Value [%]
P
re
ss
in
g
Fo
rc
e
[N]
Lead 8
Lead 16
Caution: (1) The relation of the current limit and the pressing force is a reference assuming
when the speed is 20mm/s.
(2) There will be a little variance in the actual pressing force. If the value of current
limit is small, the variance for the pressing force becomes big.
(3) Use the product with the current limit within the range specified in the graph. If
used below 20%, the pressing force would not be stable. An operation may not
be made in some cases. An operation cannot be made also when it is beyond
70%. If use in such a condition, it may extremely shorten the product life by the
degradation of insulator in the motor coil due to heat generation.
(4) When the approaching speed (setting in the position table) to the pressing start
position is 20mm/s or less, the pressing operation will be made with the
approaching speed. In this case, also, the pressing force would not be stable. In
such cased, check in advance that the actuator can be used with no problem
before start using.