IAI America RCP4CR-SA7C User Manual
Page 44

1. Checking the Product
38
Ɣ SA7C, SA7R
[N]
Current Limit Value
Lead 4
Lead 8
Lead 16
Lead 24
20%
192
96
48
32
30%
288
144
72
48
40%
385
192
96
64
50%
481
240
120
80
60%
577
288
144
96
70%
673
336
168
112
* These are the reference values at 20mm/s of pressing speed.
0
100
200
300
400
500
600
700
800
Pressing Force [N]
Current-Limiting Value [%]
Lead 8
Lead 16
Lead 24
Lead 4
SA7C/SA7R Current Limiting Values and Pressing Force
0 10 20 30 40 50 60 70 80
Caution: (1) The relation of the pressing force and current limiting value is a reference. There will be a
little variance in the actual pressing force.
(2) If the current limiting value is low, the pressing force may largely vary.
(3) The movement speed at the pressing operation is fixed to 20mm/s.
The graph shows the values when pressing with 20mm/s, and it differs if the speed
changes.