beautypg.com

Gilderfluke&Co BR-SDC Serial Device Controller User Manual

Page 41

background image

String

Sent

Multiplexer

Selected

AT+++4

AT+++5

AT+++6

AT+++7

AT+++8

Tx = #4, Rx = #4

Tx = #5, Rx = #5

Tx = #6, Rx = #6

Tx = #7, Rx = #7

Tx = #8, Rx = #8

If more numbers (1-8) are received before the (0x0D), then you can

choose to route data to more than one of the multiplexed ports a the same
time. The first valid number between 1 and 8 sets the port that will be used of
receiving serial data and routing to the Br-SDC8ʼs ʻConfig./Mux. RS-232 portʼ
(female DE-09) or ʻMux./RS-422ʼ (female Rj-12) ports.

As an example, to send serial data out ports 3, 5, and 7, and listen to port 5

for any serial data which is returned, you would send the string: ʻAT+++537
ʼ

2) ¼-J6 input bits 0, 1, 2 and 3: A binary pattern of bits presented on these four

input pins will select which multiplexer output is to be used:

Binary

Number

Bit3

Pin #6

(+8)

Bit2

Pin #7

(+4)

Bit1

Pin #8

(+2)

Bit0

Pin #9

(+1)

Multiplexer

Selected

0

1

2

3

4

5

6

7

Off

Off

Off

Off

Tx = ALL, Rx = #1

Off

Off

Off

On

Tx = #1, Rx = #1

Off

Off

On

Off

Tx = #2, Rx = #2

Off

Off

On

On

Tx = #3, Rx = #3

Off

On

Off

Off

Tx = #4, Rx = #4

Off

On

Off

On

Tx = #5, Rx = #5

Off

On

On

Off

Tx = #6, Rx = #6

Off

On

On

On

Tx = #7, Rx = #7

Gilderfluke & Co.• 205 South Flower Street • Burbank, California 91502 • 818/840-9484 • 800/776-5972 • fax 818/840-9485