AMX Modero NXD-500i User Manual
Page 68
Setup Pages and Descriptions
62
NXD-500i 5" Wall/Flush Mount Touch Panel with Intercom
G4 Web Control Page
The G4 Web Control page (FIG. 47) centers around enabling and disabling both the display and control
of your panel (via the web). An external PC running a VNC client, installed during the initial
communication to the G4 panel, makes this possible.
Each panel supports the open standard Virtual Network Computing (VNC) interface. These panels
contain a VNC server that allows them to accept a connection from any other device running a VNC
client. Once a connection is established to that target device, the client can control the touch panel
remotely. The elements of the G4 Web Control page are as follows:
FIG. 47
G4 Web Control page
G4 Web Control Page Elements
Back:
Saves the changes and returns to the previously active touch panel page.
Connection Status icon:
This visual display of the connection status allows the user to have a current
visual update of the panel’s connection status regardless of what page is
currently active.
• A Lock only appears on the icon if the panel has established a connection
with a currently secured target Master (requiring a username and password).
G4 Web Control Settings:
Sets the IP communication values for the touch panel and contains:
Enable/Enabled
• The Enable/Enabled button allows you to toggle between the two G4
activation settings:
- Enable - deactivates the G4 Web Control feature on the panel.
- Enabled - activates the G4 Web Control feature on the panel and allows
an external PC running a VNC client to access the panel after the
remaining fields are configured.
Network Interface Select
Displays the detected method of communication to the web:
• Wired is used when a direct Ethernet connection is being used for
communication to the web. This is a default setting.
Web Control Name
Allows entry of a unique alphanumeric string used as the display name of the
panel within the Manage WebControl Connections window of the new NetLinx
Security browser window.
• This Web Control tab displays a G4 icon alongside the link to the Web Control
Name given to this panel (FIG. 48).
Web Control Password
Allows entry of the G4 Authentication session password associated for VNC
web access of this panel.
Web Control Port
Allows entry of the VNC Web Server’s port value.
• Default value is 5900.
Maximum Number of
Connections
This read-only field displays the maximum number of users that can be
simultaneously connected to the target panel via the Web.
• Default value is 1.