AMX Modero NXD-500i User Manual
Page 107
Programming
101
NXD-500i 5" Wall/Flush Mount Touch Panel with Intercom
"^" Button Commands (Cont.)
^ENA
Enable or
disable buttons
with a set
variable text
range.
Syntax:
"'^ENA-
Variable:
variable text address range = 1 - 4000.
command value = (0= disable, 1= enable)
Example:
SEND_COMMAND Panel,"'^ENA-500.504&510.515,0'"
Disables button pushes on buttons with variable text range 500-504 & 510-515.
^FON
Set a font to a
specific Font ID
value for those
buttons with a
defined address
range.
Font ID numbers are generated by the TPDesign4 programmers report.
Syntax:
"'^FON-
Variable:
variable text address range = 1 - 4000.
button states range = 1 - 256 for multi-state buttons (0 = All states, for General buttons
1 = Off state and 2 = On state).
font value = Range = 1 - XXX. Refer to theDefault Font Styles and ID Numbers table on
page 85.
Example:
SEND_COMMAND Panel,"'^FON-500.504&510.515,1&2,4'"
Sets the font size to font ID #4 for the On and Off states of buttons with the variable text
range of 500-504 & 510-515.
The Font ID is generated by TPD4 and is located in TPD4 through the Main menu.
Panel > Generate Programmer's Report >Text Only Format >Readme.txt.
"^" Button Commands (Cont.)
^GDI
Change the
bargraph drag
increment.
Syntax:
"'^GDI-
Variable:
variable text address range = 1 - 4000.
bargraph drag increment = The default drag increment is 256.
Example:
SEND_COMMAND Panel,"'^GDI-7,128'"
Sets the bargraph with variable text 7 to a drag increment of 128.