Ronan XSD-1000 User Manual
Page 77
- New Installation User Software Setup -
XDS-1000 Monitoring System
07 June 2007
These steps, at a minimum must be performed to use the XSD-1000 System:
Administrative Options – File – Log File Creation
Set the interval for Log File Creation. (‘Daily’ will create a new Log File every day, etc.)
Administrative Options – Configure – Detectors
Select the number of detectors and their availability here. This menu determines the total
number of detectors for your system, and their basic configuration (Single/Dual).
User Setup – Detector Names Status
Type the names of each detector to identify them (North, East, Top-Left, etc.)
Administrative Options – Configure – Detector Locations
Move the detector boxes around the truck at their appropriate locations. Remember that
Detector 1 is tied to Remote I/O Module Address 7, Detector 2 is tied to Address 8, etc.
Administrative Options – Configure - System ID
Type in a unique ID for this system. If you are using multiple systems linked together
over your LAN system, each system MUST have a unique ID (Lower Gate, North
Entrance, etc).
Perform the following if you plan to use the Quality Assessment Package:
Administrative Options – Quality Assessment – Replace Components – Set
Sensitivity Check Interval
Normally this is 365 days, but can be whatever you set as your standard (a value of 0
disables the warning).
Administrative Options – Quality Assessment – Replace Components – Replace
Detectors
You will need to ‘replace’ (first time is install) the detectors to put them into the
database.
Administrative Options – Quality Assessment – Replace Components – Replace Test
Source
This also must be done to determine the Sensitivity Check Allowances.
Administrative Options – Quality Assessment – Replace Components – Perform
Detector Sensitivity Check
This must be done to establish a reference base of values for future Sensitivity Checks.