Ronan XSD-1000 User Manual

Page 13

background image

12

Detector Names/Status

NOTE: the number of detectors displayed here is defined in the Administration Menus
under Configure – Detectors. This should be done before enabling any detectors.

Enter the names of each detector for clarity (North, Top, etc.), and each detector’s status
(Enabled/Disabled). Each detector should have a unique name for identification
purposes. The names you select will appear over the green box displaying that detector’s
averaged counts during Background mode, and the raw counts for that detector during
Truck Present mode. The names will also appear in the Log File report if an alarm occurs
for that detector. To change the Detector Names, highlight the name in the box, and type
in the new name.

All operational detectors’ status should be ‘Enabled’. Use the ‘Disable’ function if a
detector fails in order to disable constantly triggering the I/O Failure Alarm, until the
detector problem is resolved.

To change a detector’s status (Enabled/Disabled), click on the box. A check mark means
Enabled, a blank box means Disabled.

The detector values next to each check-box under the ‘Detector Enabled’ column are the
names used to wire the detectors to the proper Remote I/O modules (1A, 2A, etc.).