beautypg.com

Rate menu – Ronan X96S WEIGH SCALE User Manual

Page 21

background image

17

Rate Menu

The Rate Config menu is used to configure the parameters associated with the Rate measurement. It contains the following
items:

ITEM

FUNCTION

Units

Shows, and allows the user to set, the rate units used

Low Range

Shows, and allows the user to set, the rate value to be mapped to 4ma on the current
loop output, if rate is selected to control that current loop.

High Range

Shows, and allows the user to set, the rate value to be mapped to 20ma on the current
loop output, if rate is selected to control that current loop.

Units is one of the following:

Units

MEANING

lb/h

pounds per hour

STon/h

Short Tons per hour

LTon/h

Long Tons per hour

STon/min

Short Tons per minute

LTon/min

Long Tons per minute

lb/min

pounds per minute

oz/min

ounces per minute

MetTon/h

Metric Tons per hour

kg/h

kilograms per hour

MetTon/min

Metric Tons per minute

kg/min

kilograms per minute

kg/sec

kilograms per second