Ransburg, Tubing bundle nomenclature, Table a tubing bundle length – Ransburg RMA Indirect A11600 User Manual
Page 91: Table b high voltage cable length, Rma-303 indirect charge - parts identification

NOTE:
For lengths above 15 ft., the SA1, SA2, and BRK require the
next larger nominal size ID tubing. This tubing is to be sup-
plied by user or integrator.
The turbine air (TA) to be supplied at a maximum length of 6 ft.
User or integrator must increase to 12mm OD tube after 6 ft.
Outer Shaping Air (Outer Air)
Inner Shaping Air (Inner Air)
Bearing Air Supply
Bearing Air Return
Dump Trigger
Dump Out
Paint Trigger
Paint Supply
Solvent Trigger
Solvent Supply
Turbine Air Supply
Low Voltage Cable Port
Fiber Optic Cable Port
Cup Wash Air
Cup Wash Air Trigger
Brake Air
Ground Cable
Tubing Bundle Nomenclature
SAO
SAI
BA
BRG, RTN
PD
DL
PT
P
ST
SOL
TA
LV
FO
CWA
ATI
BRK
GND
Air Tubing (Not Included)
15' Long Tubing Assembly
30' Long Tubing Assembly
TABLE A
Tubing Bundle Length
0
1
2
N/A
15 ft.
30 ft.
Dash
No.
"H"
Description
High Voltage Cable Assy. (Not Included)
High Voltage Cable Assy., Shielded, Non-Metallic Cen. Cond., 15 Ft.
High Voltage Cable Assy., Shielded, Non-Metallic Cen. Cond., 20 Ft.
High Voltage Cable Assy., Shielded, Non-Metallic Cen. Cond., 25 Ft.
High Voltage Cable Assy., Shielded, Non-Metallic Cen. Cond., 50 Ft.
High Voltage Cable Assy., Shielded, Non-Metallic Cen. Cond., 75 Ft.
High Voltage Cable Assy., Shielded, Non-Metallic Cen. Cond., 100 Ft.
High Voltage Cable Assy., Shielded, Non-Metallic Cen. Cond., 100 Ft.
TABLE B
High Voltage Cable Length
Description
N/A
A10560-16
A10560-20
A10560-25
A10560-50
A10560-75
A10560-100
A10560-100
"N"
0
1
2
3
4
5
6
7
Dash
No.
RMA-303 Indirect Charge - Parts Identification
Ransburg
87