Ransburg, Air filtration requirements – Ransburg RMA Indirect A11600 User Manual
Page 31

Filter
Model No.
HAF-503
RPM-417
RPM-418
HAF-15 Element, One
RPM-32 Elements,
Carton of 4
RPM-33 Elements,
Carton of 8
Pre-filter, removes coarse amounts of oil, moisture & dirt. Used
upstream of RPM-417 pre-filter (used in systems with poor air
quality).
Pre-filter, coalescing type, 136 SCFM, 98.5% efficiency particulate
removal .3 to .6 micron, max. aerosol passed 1.0 micron, max.
solid passed .4 micron (dependent upon scfm requirement per
applicator, one RPM-417 can be used with up to three RMA-303
assemblies).
Bearing air filter, coalescing type, 19 SCFM, 99.995% efficiency
particulate removal .3 to .6 micron, max. aerosol passed .6 micron,
max. solid passed .2 micron (one per applicator).
Description/Specifications
Replacement
Element Part No.
AIR FILTRATION REQUIREMENTS
> Each applicator must have its own filter
for bearing air.
Recommended: RPM-418 or equivalent
NOTE
> Air must be properly filtered to ensure
extended turbine life and to prevent contam-
ination of the paint finish. Air which is not
adequately filtered will foul the turbine air
bearings and cause premature turbine failure.
The correct type of filters must be used in
an RMA-303 system. The filter elements
must be replaced on a regular schedule to
assure clean air.
>
It is the end user’s responsibility to en-
sure clean air at all times. Turbine failure
resulting from contaminated air will not
be covered under warranty.
Figure 5 shows the pre-filter(s) and bearing
air filter which are recommended for use
in RMA-303 systems. If other filters are
incorporated in the system, the filters to be
used must have filtering capacities equal
or better than those shown in "Air Filtration
Requirements" above.
>
The user must ensure the bearing air
supply is not inadvertently turned off
while the RMA-303 air motor is turning.
This will cause air bearing failure.
C A U T I O N
!
RMA-303 Indirect Charge - Installation
Ransburg
27
LN-9252-06.4