beautypg.com

Ransburg, Rma-303 indirect charge - parts identification – Ransburg RMA Indirect A11600 User Manual

Page 90

background image

Robot Adapter

When ordering, use A11678-ABCDE as indicated by Tables A, B, C, D, and E. Up to five digits must

follow the basic part number, for example:

A11678 - X X X X X

Tubing Bundle Length

Basic Part Number

High Voltage Ground

Cable Assy.

High Voltage Cable Length

Fiber Optic

Cable Length

(Table A)

(Table B)

(Table E)

(Table C)

A11678-XXXXX TUBING BUNDLE ASSEMBLY MODEL

IDENTIFICATION

(Table D)

After installing A11680-00 ground cable assembly, tighten nut to 175 lbs•in (19.77 Nm)torque. Check resistivity from

A11679-00 robot plate to ring. Terminal at end of cable must be 10 ohms or less.

Apply A11545 lubricant onto face sparingly to prevent galling. Torque to 170 lbs•in max.

(19.21 Nm).

Apply 7969-031 to threads as required.

Install tube inserts fully into tubing before installing tubing into fitting.

Apply 7969-10 thread sealer to threads prior to assembly.

PARTS LIST BULLET DEFINITION TABLE (Figures 69a and 69b)

11

10

7

4

3

RMA-303 Indirect Charge - Parts Identification

Ransburg

86

LN-9252-06.4