beautypg.com

Ransburg, Mounting, Electrical & fiber optic connections – Ransburg RMA Indirect A11600 User Manual

Page 32: Fluid connections, Typical installation, Air heater

background image

MOUNTING

The RMA-303 is equipped with a quick disconnect

assembly. The quick disconnect feature consists

of a robot plate which is permanently attached

to the robot through a wrist adapter plate, and a

mating bell plate which is a part of the RMA-303

atomizer assembly. The atomizer is secured to

the robot plate with a threaded retaining ring.

ELECTRICAL & FIBER

OPTIC CONNECTIONS

The fiber optic connection is made on the back of

the atomizer's robot plate. The fiber optic cable

comes preassembled with connectors that are

secured in place by set screws tightened from the

side of the robot plate. An adequate ground must

be provided to the mounting plate to ensure that

fluid fittings , etc. are at ground potential.

Maximum amount of splices for any length of cable

is 3. The speed detection signal may be affected if

splices are exceeded. Length in any combination

for the fiber optic is 100-feet.

FLUID CONNECTIONS

The paint, solvent, and dump fluid tubing are con-

nected on the back of the robot plate with stainless

steel compression fittings and PFA tubing. Fluid

tubing requirements are shown in "Fluid Tubing

Connection Requirements" below.

TYPICAL INSTALLATION

Figure 3 shows a Typical Installation of the RMA-

303 and the wiring installation of the applicator

with the MicroPak.

AIR HEATER

Connect air heater to turbine air tubing. Air heater

connection to bearing air is not rquired.

6mm ID / PFA

A11283-00 Nylon Recirculation

Tube-In-Tube

10mm ID / PFA

Paint Line (P)

Cup Wash Solvent Line (SOL)

Dump Line (DL)

200 psi max. (1379 kPa)

150 psi max. (1033 kPa)

200 psi max. (1379 kPa)

Fixed Atomizer

Pressure (Maximum)

FLUID TUBING CONNECTION REQUIREMENTS

RMA-303 Indirect Charge - Installation

Ransburg

28

LN-9252-06.4