MOUNTING
The RMA-303 is equipped with a quick disconnect
assembly. The quick disconnect feature consists
of a robot plate which is permanently attached
to the robot through a wrist adapter plate, and a
mating bell plate which is a part of the RMA-303
atomizer assembly. The atomizer is secured to
the robot plate with a threaded retaining ring.
ELECTRICAL & FIBER
OPTIC CONNECTIONS
The fiber optic connection is made on the back of
the atomizer's robot plate. The fiber optic cable
comes preassembled with connectors that are
secured in place by set screws tightened from the
side of the robot plate. An adequate ground must
be provided to the mounting plate to ensure that
fluid fittings , etc. are at ground potential.
Maximum amount of splices for any length of cable
is 3. The speed detection signal may be affected if
splices are exceeded. Length in any combination
for the fiber optic is 100-feet.
FLUID CONNECTIONS
The paint, solvent, and dump fluid tubing are con-
nected on the back of the robot plate with stainless
steel compression fittings and PFA tubing. Fluid
tubing requirements are shown in "Fluid Tubing
Connection Requirements" below.
TYPICAL INSTALLATION
Figure 3 shows a Typical Installation of the RMA-
303 and the wiring installation of the applicator
with the MicroPak.
AIR HEATER
Connect air heater to turbine air tubing. Air heater
connection to bearing air is not rquired.
6mm ID / PFA
A11283-00 Nylon Recirculation
Tube-In-Tube
10mm ID / PFA
Paint Line (P)
Cup Wash Solvent Line (SOL)
Dump Line (DL)
200 psi max. (1379 kPa)
150 psi max. (1033 kPa)
200 psi max. (1379 kPa)
Fixed Atomizer
Pressure (Maximum)
FLUID TUBING CONNECTION REQUIREMENTS
RMA-303 Indirect Charge - Installation