beautypg.com

Ransburg, Quick release collet removal and replacement – Ransburg RMA Indirect A11600 User Manual

Page 68

background image

Figure 49: Valve Extraction

Fiber Optic Cable and Transmitter

Removal/Replacement

Removal

Remove the atomizer body from the atomizer

extension as discussed earlier.

Remove the fiber optic nut from the inside cavity

where the air bearing spindle seats using the

fiber optic transmitter tool (78279-00). Loosen

and remove nut. Carefully pull out the fiber optic

transmitter from the front while pushing the cable

from the opposite end. Loosen the black knurled

nut holding the cable to the transmitter. Pull the

nut off of the cable. The cable can be pulled out

from the back side of the atomizer body.

Replacement

To replace, slide the new fiber optic cable through

the hole in the back side of the atomizer body until

it protrudes well out in front of the body. Slide the

black knurled nut over the fiber optic cable ap-

proximately 1/4-inch (onto the black portion of

the cable). Install the glass fiber portion into the

rear of the transmitter until it bottoms. Slide the

nut forward and tighten securely. Slide the entire

assembly back into the atomizer body. Pull gently

from the back side while pushing the transmitter

from the front. Slide fiber optic nut over transmitter

and tighten securely with transmitter tool (78279-

00). Feel transmitter after installation. It should

not be loose when properly installed.

Figure 50: Fiber Optic Removal/Replacement

QUICK RELEASE

COLLET REMOVAL AND

REPLACEMENT

(Atomizer Body and Cup Wash
Manifold) (Figure 51)

If collet or o-rings become damaged, they can be

removed and replaced. To remove the collet, use

a flat blade screwdriver or needle nose pliers. If

using the screwdriver, lift collet with fingers and

place screwdriver blade under the head. Pry up

in several places if necessary until removed. If

using the pliers, grasp the head between the inside

and outside diameter and pull straight out or by

pulling with a rocking motion.

Remove the o-ring with a

plastic pick device. Do

not scratch or nick the sealing surfaces.

To replace o-ring and collet, lubricate the o-ring

with petroleum jelly and insert into hole and make

sure it lies flat on its seating surface. Align the

collet with the hole and push straight in. Some

collets are tighter than others by design and may

require a rocking motion while pushing.

This procedure is the same for all the collets, in

the atomizer body, and the cup wash manifold.

RMA-303 Indirect Charge - Maintenance

Ransburg

64