Ransburg, Aerobell - installation – Ransburg Aerobell (Std.) Rotary Atomizer A12381 User Manual
Page 37

2. Loosen one of the connector nuts from the high
voltage splitter assembly.
Apply dielectric grease (LSCH0009-08) on the
cascade end of the high voltage cable and in the
splitter assembly.
Slide the fitting and start threading on to the high
voltage cascade tube threads. (Each piece of
the fitting may have to be slid into place starting
with the sleeve followed by the plastic gripper and
then the nut.)
Turn the nut hand tight.
Wrench tighten the nut 1/2 turn.
Pull on cable to ensure a secure fitting. If the
cable is loose and can be pulled free, then reinsert
cable into cascade and follow these steps again
with an additional 1/2 turn on the nut.
2. Attach the ring lug of the green ground wire
(shield cables A10560-XX only) securely to a
known good earth ground source.
High Voltage Splitter Installation
(78152-00) (See Figure 8)
The splitter can be used for up to four atomizers.
1. Remove nut from end of cascade extension
tube (78441-00). Apply a small amount of dielectric
grease to tip of the banana jack of the high voltage
splitter assembly. Slide the banana jack into the
cascade tube until it bottoms. Tighten onto threads
by turning clockwise until snug.
78152-00
HV SPLITTER
74593
CASCADE
PLUG FOR UNUSED PORT
(3) SUPPLIED
HIGH VOLTAGE WIRE FROM APPLICATOR
(NON-REPAIRABLE)
Insert the high voltag e cable through the back of
the nut all the way through the nut assembly to
the banana plug socket in the splitter body.
Turn the nut hand tight.
Wrench tighten the nut 1/2 turn.
Pull on cable to ensure a secure fitting. If the
cable is loose and can be pulled free, then reinsert
cable into high voltage splitter and follow these
steps again with an additional 1/2 turn on the nut.
3. Attach the ring-lug of green ground wire
(shielded cables A10560-XX only) securely to a
known good earth ground source.
Voltage Master 2 (78789) Cable
Installation
The Voltage Master 2 contains a control panel
and a power supply (LEPS5001). To install the
high voltage cable, loosen the nut on the top of
the LEPS5001-02 power supply tank and insert
the high voltage cable through the nut and rubber
gromment and push into tank until the banana jack
is fully seated. Tighten the nut firmly by hand to
grip the cable.
To connect multiple applicators, you can connect a
high voltage cable from LEPS5001-02 tank to the
input of a LEPS5000-05 junction tank. Up to five
(5) applicators can be supplied from the junction
tank. High voltage cable connection on this tank
is the same as the Voltage Master 2 tank.
Another method for connecting multiple applicators
from the Voltage Master 2 is to "daisy chain" by
using high voltage fittings A10030-00 and A10030-
02 (see "Figure 3 - Typical Multiple Applicator
Configuration Voltage Master 2 and PulseTrack
2 Speed Control" in the "Introduction" section).
Aerobell - Installation
33
LN-9264-08.2
Ransburg