Ransburg, Air filtration requirements – Ransburg Aerobell (Std.) Rotary Atomizer A12381 User Manual
Page 29
>
Air must be properly filtered to ensure
extended turbine life and to prevent
contamination of the paint finish. Air which
is not adequately filtered will foul the turbine
air bearings and cause turbine failure. The
correct type of filters must be used in an
Aerobell system. The filter elements must
be replaced on a regular schedule to assure
clean air.
>
It is the user’s responsibility to ensure
clean air at all times. Turbine failure
resulting from contaminated air will not
be covered under warranty. If other filters
are incorporated in the system, the filters to
be used must have filtering capacities equal
or better than those shown in "Air Filtration
Requirements Chart".
>
The user must ensure the bearing air
supply is not inadvertently turned off while the
Aerobell air motor is turning. This will cause
air bearing failure.
C A U T I O N
!
AIR FILTRATION REQUIREMENTS
Ransburg
Filter Model No.
HAF-515
RPM-417
RPM-418
HAF-5 Element,
One
RPM-32 Elements,
Carton of 4
RPM-33 Elements,
Carton of 8
Pre-filter, removes coarse amounts of oil, moisture and
dirt. Used upstream of RPM-417 pre-filter (used in
systems with poor air quality).
Pre-filter, coalescing type, 136 SCFM, 98.5% efficiency
particulate removal .3 to .6 micron, max. aerosol passed
1.0 micron, max. solid passed .4 micron (dependent
upon SCFM requirement per applicator, one RPM-417
can be used with up to three Aerobell assemblies).
Bearing air filter, coalescing type, 19 SCFM, 99.995%
efficiency particulate removal .3 to .6 micron, max.
aerosol passed .6 micron, max. solid passed .2 micron
(one per Aerobell).
Description / Specifications
Replacement
Element Part No.
> Each applicator must have its own filter
for bearing air. Recommended: RPM-418
or equivalent.
NOTE
Aerobell - Installation
25
LN-9264-08.2