Ransburg, High voltage cable assemblies, High voltage cable configurations – Ransburg Aerobell (Std.) Rotary Atomizer A12381 User Manual
Page 36: High voltage installation configurations

6. Any other interlocks required by local code,
national code, or international code.
7. High voltage must be interlocked with the
booth entry door.
HIGH VOLTAGE CABLE
ASSEMBLIES
General Instructions
1. When routing cable, ensure that no chaffing,
binding, or pulling on the cable will occur. Maintain
at least a 4-inch bend radius. When possible,
sleeve cable with the appropriate sized tubing for
external cable protection. Torsion stress should
be minimized.
2. Considerations should be taken when routing
cables next to other cabling and fluid tubing. Be
cognizant of the placement of such cable near
control wires and fluid lines. Follow NEC wiring
standards where applicable. Separation of AC,
control wiring, and fluid tubing is advisable.
3. To ensure that all cable connections are clean
and free of foreign materials, wipe with Naphta.
This also applies to the cascade, splitter, and
applicator connectors.
4. Apply dielectric grease (LSCH0009-08) on
all cable end connectors (cascade, splitter, and
applicator) to displace any encapsulated air.
5. Each time a cable is replaced, the nut assembly
(78441-00) must also be replaced.
6. Ensure that no conductive sponges are used
in any connector!
7. A10560-XX cables are not to be modified in
the field. To do so will void any and all warranties
that may exist.
HIGH VOLTAGE CABLE
CONFIGURATIONS
There are two (2) high voltage cable assemblies
available:
A10560-XX is a shielded cable and is the most
flexible. It is available in several lengths per the
"Accessories" chart in the "Parts Identification"
section.
79006-XX is a metallic core conductor cable with
a polyethylene jacket and an exterior sleeve. It
comes pre-assembled with banana jacks at each
end.
A third option is to build your own cable to a specific
length not to exceed 100-ft. (30.5 meters) in length.
A non-shielded metallic conductor cable (SSW-
1064) is used. the end user must intall the EPS-
4245 banana jacks. It is hightly recommended
that an insulating jacket (79007-00) be installed
over the assembly to protect it from damage.
HIGH VOLTAGE
INSTALLATION
CONFIGURATIONS
Cascade RP1000 Installation
(74793-XX) with MicroPak Control
1. Loosen connector nut assembly from the
cascade.
Apply dielectric grease (LSCH0009-08) on the
cascade end of the high voltage cable and in the
cascade tube.
Insert the cable through the back of the
compression nut followed by the plastic gripper
and sleeve
(78441-00).
Insert the high voltage cable through the cascade
high voltage tube, all the way through the nut
assembly to the banana plug socket in the cascade
tube assembly.
Aerobell - Installation