Vector R Series Classic Applicators - Parts Identification

57

Ransburg

AH-06-02.12

WATERBORNE

ISOLATION SYSTEM

INSTALLATION

GUIDELINES

Using waterborne coating with electrostatic equip-

ment requires that the fluid source be isolated from

ground. Precautions should be taken to ensure

operator safety and system efficiency.

The following guidelines should be followed:

• The fluid lines and source MUST be isolated

from ground. An isolating paint stand or similar

isolating (non-porous) material MUST be used.

†

Typical installations to spray non-flam-

mable conductive materials (waterborne

materials) must not be used to handle flam-

able materials (solvent based materials).

W A R N I N G

!

• Isolation stands MUST be at least 18-inches

from grounded booth walls, chain link fences,

or other grounded objects.

• Air hoses to the pressure pot or pump on the

insulating stand should be non-conductive

plastic. Many rubber hoses will have static

grounding circuits or carbon content and are

NOT suitable for this application

• All charged (isolated) systems MUST be inside

a fence or cage to prevent contact by personnel.

An interlock system MUST be provided that

WATERBORNE HOSE

FITTING INSTALLATION

For 79520 R90 Classic - Waterborne: Ransburg

supplies the waterborne fluid hose factory pre-as-

sembled to the applicator unit. Standard hose

lengths are 10m, 15m, and 25m. To modify the

hose length, use the following procedures. All

adjustments must be made at the supply end of

the system.

1. Remove the male connector and swivel fitting

from the end of the fluid hose by turning the nut

of the male connector counter-clockwise while

holding its main body.

2. Remove the male connector nut from the fluid

hose.

3. Determine the hose length that is needed and

cut the hose off squarely.

†

Never use wood products, wooden box-

es, pallets, or boards as an isolator. Wood

contains moisture and is a poor insulator.

Electrical current passing through these ma-

terials can ignite them, causing a hazardous

condition.

C A U T I O N

!

interrupts high voltage flow to the applicator if

the gate is opened.

• Air regulators for pots or pumps should be

mounted remotely outside the fence or cage

area to facilitate changes in pressure without

shutting the system down.

• Grounding hooks at the cage MUST be used

to ground the system when personnel are

working close by.

• Fluid lines to the applicator MUST be protected

from scraping and abrasion on the floor or

sharp metal edges that could lead to voltage

pin holing and loss of kV on the charged system.

• Cleanliness and maintenance are extremely

critical.

• Refer to "Installation - 79503 R90 Solventborne,

79504 R70 Solventborne" in the "Installation"

section.