Vector R Series Classic Applicators - Installation

22

Ransburg

AH-06-02.12

†

Any user supplied air hose must be rat-

ed at a minimum working pressure of 100

psig (6.9 bar).

C A U T I O N

!

Fluid Hose Recommendations

Ransburg recommends using a 78548-XX fluid

hose assembly. This assembly is made to spe-

cifically fit the fluid fitting size engineered into

the applicator. This hose is available from your

authorized Ransburg distributor. Available hose

lengths are listed in "Accessories" in the "Parts

Identification" section of this manual.

Air and Fluid Hose Installation

The fluid inlet fitting for the Vector applicator is

3/8-18 NPSM(M). When installing a fluid hose,

tighten the fitting adequately to prevent any fluid

leaks. The air inlet fitting is 1/4-18 NPSM(M).

When installing the air hose, use a wrench to hold

the air inlet fitting on the Vector and tighten the

air hose fitting enough to prevent any air leaks.

Routing of Air and Fluid Hoses

Starting at the applicator, route the air hose along

the same path as the high voltage cable to the

power supply. The fluid hose can be run with the

high voltage cable and air hose or it can be sep-

arate and run to the fluid source. Do not expose

the hoses to high temperatures (over 120°F) and/

or conditions such as moving parts, foot traffic,

vehicle traffic, etc.

†

Any user supplied fluid hose must be rat-

ed at a minimum working pressure of 100

psig (6.9 bar).

C A U T I O N

!

†

When securing the air hose, fluid hose,

and high voltage cable together, take care

not to use items such as wire or anything

that might cut into the hoses or cable. If

wire ties are used, they should only be tight

enough to secure the cable and not so tight

that they might restrict fluid and air flow.

W A R N I N G

!

Adjust the length of the air hose to the high voltage

power supply and install the fitting to the hose.

PAINT PREPARATION

A proper paint mixture is essential to electrostatic

operation. Paint test equipment may be obtained

through your Ransburg distributor. Reference

Technical Manual "Paint Related Information for

REA, REM, Vector, and M90 Guns" for paint for-

mulation information. For further paint formulation

and testing procedures, consult your Ransburg

distributor and/or your paint supplier.

†

An air filter

MUST be installed to permit

proper functioning of the air flow switch in-

side the power supply.

C A U T I O N

!

2. Ransburg recommends that a fluid filter be

installed at the output of the fluid supply (pressure

pot, pump, circulating system, etc.). It is the end

user's responsibility to install the proper filter that

meets their system's requirements.

Air Hose Recommendation

Ransburg recommends using a 78547-XX air

hose assembly that may be ordered through

your authorized Ransburg distributor. This hose

performs best with the Vector to reduce air hose

stiffness along with weight reduction. Available

hose lengths are listed in "Accessories" in the

"Parts Identification" section of this manual.