Unscrew the reduction gear box fixing screws (1, fig. 22).

GENERAL PUMP

A member of the Interpump Group

MW/S SERIES

Page 9

Advance the half supports completely in the direction of the pump head to allow the crankshaft to come

out. To facilitate this operation, use special tool (p/n F27566200) (1, fig. 19).

Remove the three upper half-bearings of the half supports (1, fig. 20).

Ref 300791 Rev.C