beautypg.com

Mw/s series – General Pump MW Repair Manual User Manual

Page 22

background image

GENERAL PUMP

A member of the Interpump Group

MW/S SERIES

Take care to fully and properly insert the O-ring in its housing on the cover to prevent

damage during screw tightening.

Calibrate the screws with a torque wrench as indicated in paragraph 3 “Screw Tightening Calibration”.

Insert the ring gear support ring in the crankshaft shank (1, fig. 73) to end stroke (1, fig. 74).

Page 22

Apply key 22 x 14 x 80 in the shaft housing (1, fig. 75) and insert the ring gear on the shaft (1, fig. 76).

The ring gear must be assembled making sure that the two M8 holes (to be used for

extraction) be turned outward of the pump (1, fig. 76).

Ref 300791 Rev.C