GENERAL PUMP

A member of the Interpump Group

MW/S SERIES

Extract the seal ring using the tool extractor hammer (1, fig. 36).

Page 13

Remove the two spindle locking retaining rings Ø120 (1, fig. 37).

Remove the spindle (1, fig. 38 and extract the con-rod (1, fig. 39).

Ref 300791 Rev.C