Remove the tool for blocking the con-rods #F27566200 (1, fig. 32). Insert the upper half-bearings between

the con-rods and the shaft (1, fig. 66).

For proper assembly of the half-bearings, ensure that the reference tab on the

half-bearings are positioned in their housing on the half support (1, fig. 67).

GENERAL PUMP

A member of the Interpump Group

MW/S SERIES

Tighten the 8 M10 x 40 screws (1, fig. 56). Calibrate the screws with a torque wrench as indicated in

paragraph 3 “Screw Tightening Calibration”.

Apply the lower half-bearings to the caps (1, fig. 68) ensuring that the half-bearing reference notches are

positioned in their housing on the cap (1, fig. 68).

Fasten the caps to the half supports by means of M10 x 1.5 x 80 screws (1, fig. 69).

Note the correct assembly direction of the caps. Numbering must be turned upward.

Calibrate the screws with a torque wrench as indicated in paragraph 3 “Screw Tightening Calibration),

bringing the screws to tightening torque at the same time.