Extract the outlet valve unit with the use of an extractor hammer (#F27516400) to be applied on the M10

hole of the valve guide (1, fig. 136).

Unscrew the 8 M16 x 45 screws of the suction valve cover (1, fig. 137) and remove the cover (1, fig. 138).

Extract the suction valve unit with the use of an extractor hammer (#F27516400) to be applied on the M10

hole of the valve guide (1, fig. 139).