To prevent damage to the seal ring, take special care when inserting the seal ring

on the pinion.

Apply O-rings on the inspection covers (1, fig. 92) and tighten with 2+2 M16 x 14 screws (1, fig. 93).

Calibrate the screws with a torque wrench as indicated in paragraph 3 “Screw Tightening Calibration”.

Insert the key 14 x 9 x 60 on the pinion. Apply plugs and lifting brackets with the use of M16 x 30 screws (1,

fig. 94). Calibrate the screws with a torque wrench as indicated in paragraph 3 “Screw Tightening

Calibration:.

Insert oil in the casing as indicated in the use and maintenance manual point 7.4

Ref 300791 Rev.C