beautypg.com

Mw/s series – General Pump MW Repair Manual User Manual

Page 44

background image

GENERAL PUMP

A member of the Interpump Group

MW/S SERIES

Page 44

After having completed assembly of the outlet valve units, apply the outlet valve cover (1, fig. 160) and

screw in the 8 M16 x 45 screws (1, fig. 161).

Apply 6 front O-rings on the pump casing (1, fig. 162).

Assembly the pump casing head (1, fig. 163) taking care not to hit the plungers and screw in the 8 M16 x 150

screws (1, fig. 164).

Proceed with calibration of the M16 x 150 screws with a torque wrench as indicated in paragraph 3,

“Screw Tightening Calibration”.

Ref 300791 Rev.C

11-12