To remove the low pressure seal, use a thickness gauge or another tool which will not damage the seal

support housing (1, fig. 175).

2.2.6 Re-assembling the Plunger Unit - Support - Seals

Proceed with re-assembly following the reverse order indicated in point 2.2.5.

Replace the pressure seals moistening the lips with silicone grease (without spreading

it), taking extra care not to damage them during liner insertion.

The O-rings and the low pressure seals must be replaced at each disassembly.

Separate the seal support from the liner (1, fig. 173) to access the pressure seals (1, fig. 174).

Ref 300791 Rev.C