beautypg.com

Mw/s series – General Pump MW Repair Manual User Manual

Page 46

background image

GENERAL PUMP

A member of the Interpump Group

MW/S SERIES

Remove the upper inspection cover, unscrewing the 2 fixing screws (1, fig. 168).

Page 46

Manually turn the shaft in such a way to bring the 3 plungers to the upper dead center position. Insert the

buffering tool (#F27632500) between the plunger guide and the plunger (1, fig. 169).

Disassemble plungers unscrewing the fixing screws (1, fig 167). Remove the plunger from the seal support

and check that its surfaces do not present any scratches, signs of wear or cavitation.

Ref 300791 Rev.C

11-12