beautypg.com

Mw/s series – General Pump MW Repair Manual User Manual

Page 35

background image

GENERAL PUMP

A member of the Interpump Group

MW/S SERIES

Page 35

Assemble the O-ring, exploded view position 19 from the Owner’s Manual (1, fig. 126) and the anti-extrusion

ring, exploded view position 23 (2, fig. 126) on the outlet valve plug.

Pay special attention to O-ring insertion in 1, fig. 123. Use special tool #F27516000

to prevent the O-ring from damage during insertion.

Insert the valve housing ring (1, fig. 124) and the spring (1, fig. 125).

Ref 300791 Rev.C

11-12