beautypg.com

Mw/s series – General Pump MW Repair Manual User Manual

Page 32

background image

GENERAL PUMP

A member of the Interpump Group

MW/S SERIES

Page 32

Assemble the suction and outlet valve units (fig. 109 and fig. 110), taking care not to invert the previously

disassembled springs.

To facilitate insertion of the valve guide in its housing, you can use a pipe resting on the horizontal guide

planes (fig. 111) and use an extractor hammer acting on the whole circumference.

Insert the O-ring, exploded position 6 from the Owner’s Manual (1, fig. 113).

Proceed with insertion of the valve units (suction and outlet) in the head, taking care to

follow the correct insertion sequence of O-rings and anti-extrusion rings.

The proper sequence of valve unit assembly on the head is as follows:

Insert the anti-extrusion ring, exploded position 5 from the Owner’s Manual (1, fig. 112).

Ref 300791 Rev.C

11-12