Agilent Technologies E8267D PSG User Manual
Page 254

240
Chapter 12
Peripheral Devices
N5102A Digital Signal Interface Module
Figure 12-1
Data Setup Menu for a Parallel Port Configuration
The N5102A module clock rate is set using the
Clock Rate
softkey and has a range of 1 kHz to
400 MHz. The sample rate is automatically calculated and has a range of 1 kHz to 100 MHz. These
ranges can be smaller depending on logic type, data parameters, and clock configuration.
Maximum Clock Rates
The N5102A module maximum clock rate depends on the logic and signal type.
and
show the warranted rates and the maximum clock rates for the various logic and signal
types. Notice that LVDS in the output mode using an IF signal is the only logic type where the
warranted and maximum rates are the same.
Table 12-1 Warranted Parallel Output Level Clock Rates and Maximum Clock Rates
Logic Type
Warranted Level Clock Rates
Maximum Clock Rates (typical)
IQ Signal Type
IF Signal Type
a
a.The IF signal type is not available for a serial port configuration.
IQ Signal Type
IF Signal Type
LVTTL and CMOS
100 MHz
100 MHz
150 MHz
150 MHz
LVDS
200 MHz
400 MHz
400 MHz
400 MHz
Clock and sample rates
Least significant bit
See the PSG User’s Guide for information
Most significant bit