background image

Chapter 6

179

Custom Arb Waveform Generator

Configuring Hardware

The Custom Arb Waveform Generator has been configured to play a single multicarrier waveform
100 milliseconds after it detects a change in TTL state from low to high at the PATT TRIG IN rear
panel connector.

10. Set the function generator waveform to a 0.1 Hz square wave at an output level of 0 to 5V.

11. On the signal generator, press

Mode

>

Custom

>

Arb Waveform Generator

>

Digital Modulation Off On

until On

is highlighted.

This generates a waveform with the custom multicarrier state and the display changes to Dig Mod
Setup: Multicarrier

.

During waveform generation, the DIGMOD and I/Q annunciators activate and the new custom
multicarrier state is stored in volatile ARB memory. The waveform should be modulating the RF
carrier.

12. Press

RF On/Off

.

The externally single–triggered custom multicarrier waveform should be available at the signal
generator’s RF OUTPUT connector 100 ms after receiving a change in TTL state from low to high
at the PATT TRIG IN.