After flush cutting

Remount the cover plate to the blade guard.

5.9

Connecting the power unit

Fundamentals

Never connect or disconnect
hoses when the unit is running.

Connect couplings with elbow pieces
to the wall saw system

Connect straight couplings to the po-
wer unit

Keep the couplings clean

Connect both ends of the hose package.
Thus the hose couplings are kept clean
and will not be damaged during trans-
port.

If the hoses can not be connected easily they are under pressure

(see below).

Relieving pressure in the hose

1)

At the power unit: Actuate the main
circuit valve or the spool valve se-
veral times

2)

At the hose: Put the supplied pres-
sure relief valve on the coupling and
srew it in

FZ

Set-up

FZ30494E

Page 25