KEYSTROKES FOR SETUP
If the MENU

key does not work, see Section 9 “Enabling & Locking Out Menu Items.”

Press Menu
Key

Press Digit Select
Key

Press Value Select
Key

___000

Output filtering

0

Send unfiltered signal

1

Send filtered signal

___000U

Baud rate

0

300 baud

4

4800 baud

1

600 baud

5

9600 baud

2

1200 baud

6

19200 baud

3

2400 baud

.

Ser 1

.

Serial Setup 1.
Press

until

Ser 1 is displayed.

Fixed Parameters
No parity
8 data bits
1 stop bit

___000U

Digital output rate.
rr = reading rate.
rr depends on gate time and
input frequency.

0

Output at reading rate rr.

1

Output at rr/2

5

Output at rr/32

2

Output at rr/4

6

Output at rr/64

3

Output at rr/8

7

Output at rr/128

4

Output at rr/16

8

Output at rr/256

__0000U

Line feed

0

No LF after carriage return

1

LF after carriage return

__0000U

Alarm data with readings

0

No alarm data

1

Alarm data with reading

__0000U

Output mode control

0

Continuous data output

1

Data output on ASCII command only

.

Ser 2

.

Serial Setup 2

__0000U

Meter address with Custom
ASCII protocol*

Select

0

thru

F

for addresses 1 thru 15.

Select

0.

thru

F.

(with decimal point) for