Laurel Electronics LAUREATE SERIES 2 COUNTER-TIMER-SERIAL INPUT METER User Manual

Page 26

background image

26

Press
Menu

Press Digit
Select Key

Press Value Select
Key

_

InPut

(continued)

_0-360

. Span from 0° to 360°. Select for phase

angles centered around 180° (Item #1).

PHASE

Phase angle modes

E

x

te

n

d

e

d

_-180+

. Span from -180° to +180°. Select for phase

angles centered around 0° (Item #1).

duty_C

Duty cycle mode

E

x

t.

A_to_b

On or Off period of square waves as a

percentage of total period (Item #1).

SEtuP

Setup

_00000

Stored totals

0

Zero totals at power-on.

1

Restore totals at power-on.

_00000

Leading zeros

0

Blank leading zeros.

1

Display leading zeros.

_00000

Scaling method 1

0

Input scale factor 1 and offset 1.

1

Use coordinates of 2 points method.

_00000

Scaling method 2

0

Input scale factor 2 and offset 2.

1

Use coordinates of 2 points method.

_00000

Operation of rear connec-
tor control inputs 1 & 2.
True = 0V or tied to
digital ground).
False = 5V or open).

0

1 = Meter Reset*, 2 = Function Reset*

1

1 = Meter Reset*, 2 = Meter Hold*

2

1 = Meter Reset*, 2 = Peak or Valley Display*

3

1 = Meter Reset*, 2 = External Gate*

4

1 = Function Reset*, 2 = Meter Hold*

5

1 = Valley Only Display**, 2=Peak Only Display**

6

1 = Function Reset*, 2 = External Gate*

7

1 = Meter Hold**, Peak or Valley Display**

8

1 = Reset Total A**, 2 = Reset Total B**

9

1 = Force Alarm1, 2 = Force Alarm2

A

1 = Meter Reset*, 2 = Display Blank*

B

1 = Function Reset*, 2 = Display Blank*

C

1 = Meter Hold*, 2 = Display Blank*

D

1 = Peak or Valley Display**, 2 = Display Blank**

E

1 = Display Blank, 2 = External Gate*

F

1 = Display Item #2, 2 = Display Item #3

With 1 and 2 at 5V or open, Display Item #1.
-------------------------------------------------------------------

* 1 & 2 both at 0V = Meter Reset (can restore
totals).
** 1 & 2 both at 0V for selections

5

,

7

,

8

,

D

=

Function Reset* (erases all totals).