beautypg.com

Laurel Electronics LAUREATE SERIES 2 COUNTER-TIMER-SERIAL INPUT METER User Manual

Page 27

background image

27

Press
Menu

Press Digit Select
Key

Press Value Select
Key

__0000

Display mode

0

Normal, overload to exponential format

1

Normal, overload to 999999

2

1 right-hand dummy zero

3

2 right-hand dummy zeros

4

Time display in seconds

5

Time display in HH.MM.SS format

6

Remote display (H, K, L commands)

7

Single-value remote display

8

Show 1

st

string value, slaved to another meter

9

Show 2

nd

string value, slaved to another meter

A

Show 3

rd

string value, slaved to another meter

B

Show 4

th

string value, slaved to another meter

C

Custom Start, Stop, Skip, Show

__0000

Counter mode

0

Basic counter

1

Extended counter

2

Extended counter, custom curve linearization

__0000

Square root

0

Linear rate input.

1

Square root rate input.

ConFiG

Configu-
ration

__0000

Not applicable

0

Set to 0.

dSPyno

Display #

____01

PEAK key action

0

Display Peak

1

Display Valley

2

Peak (1

st

push), Valley (2

nd

push)

____01

Item to display

after Meter Reset*

1

Item #1*

2

Item #2*

3

Item #3*

GAtE_t

Gate time*

_000.00 _000.00 _000.00
_000.00 _000.00

Select digit to flash.

Select

0

thru

9

for flashing digit to set gate time* in

seconds. Decimal point location is fixed for 10 ms
resolution.

.

ti_Out

.

Time-out*

_000.00 _000.00 _000.00
_000.00 _000.00

Select digit to flash.

Select

0

thru

9

for flashing digit to set time-out* in

seconds. Decimal point location is fixed for 10 ms
resolution.

_00000

Handling of overshoot
count at end of batch.

0

Do not count extra pulses after Preset. Add
Preset values to Grand Total.

1

Count all pulses. Add Preset values to Grand
Total.

2

Do not count extra pulses after Preset. Add
Preset values to Grand Total.

3

Count extra pulses after Preset. Add actual
Batch Totals to Grand Total.

_00000

Count direction

0

Reset batch to 0 and count up to Setpoint 1.

1

Reset batch to Setpoint 1 and count down.

bAtCH

Batch setup

_00000

Batch triggering

0

Use internal gate time as delay between batches

1

Use External Input B to trigger each new batch.