Laurel Electronics LAUREATE SERIES 2 COUNTER-TIMER-SERIAL INPUT METER User Manual

Page 52

background image

52

Press
Menu

Press Digit
Select Key

Press Value Select
Key

dSPyno

Display #

____01

PEAK key action

0

Display Peak

1

Display Valley

2

Peak (1

st

push), Valley (2

nd

push)

____01

Item to display

after Meter Reset

1

Item #1* (Quadrature Rate = Rate A - Rate B)

2

Item #2* (Rate A)

3

Item #3* (Rate B)

GAtE_t

Gate time*

_000.00 _000.00 _000.00
_000.00 _000.00

Select digit to flash.

Select

0

thru

9

for flashing digit to set gate time* in

seconds. Decimal point location is fixed for 10 ms
resolution.

.

ti_Out

.

Time-out*

_000.00 _000.00 _000.00
_000.00 _000.00

Select digit to flash.

Select

0

thru

9

for flashing digit to set time-out* in

seconds. Decimal point location is fixed for 10 ms
resolution.

FiLtEr

Filtering

_00000

Signal filtering

0

Adaptive moving average filter. Restarts filter for
high actual changes in signal.

1

Conventional moving average filter without reset.

_00000

Peak & Valley filtering

0

Peak* or Valley* value from unfiltered signal.

1

Peak* or Valley* value from filtered signal.

_00000

Display filtering

0

Display value of unfiltered signal.

1

Display value of filtered signal.

_00000

Adaptive filter setup

0

Set adaptive filter for normal noise.

1

Set adaptive filter for presence of high transients.

_00000

Filter time constant

0

No filter

1

0.1 sec

2

0.2 sec

3

0.4 sec

4

0.8 sec

5

1.6 sec

6

3.2 sec

7

6.4 sec

dEC.Pt1

Decimal pt1

1

.

11111

Decimal point flashes.

1

.

11111

11

.

1111

111

.

111

1111

.

11

11111

.

1

111111

.

Press to shift decimal point of reading.

dEC.Pt22

Decimal pt2

2

.

22222

Decimal point flashes.

Make the same as

dEC.Pt1

Scale and Offset scaling method if selected under

SEtuP

SCALE1

Scale
Factor 1

0.00000 0.00000 0.00000
0.00000 0.00000 0.00000

Select the digit to flash
for the Scale Value, then
press one more time
for the Scale Multiplier.

Select

-9

thru

9

for flashing first digit and

0

thru

9

for

other flashing digits. This will set the Scale Value*
from -9.99999 to 9.99999 with a fixed decimal point.
Then press to select a value from

0.00001

to

100000

in decade steps for the Scale Multiplier.

Scale Factor = Scale Value x Scale Multiplier.

OFFSt1

.

Offset 1

000000 000000 000000
000000 000000 000000

Select digit to flash.

Select

-9

thru

9

for flashing first digit and

0

thru

9

for

other flashing digits. Use

dEC.Pt1

to set the decimal

point.

SCALE2

Scale Factor 2

Make the same as

SCALE1

.

OFFSt2

.

Offset 2

Make the same as

OFFSt1

.