beautypg.com

Laurel Electronics LAUREATE SERIES 2 COUNTER-TIMER-SERIAL INPUT METER User Manual

Page 29

background image

29

Press
Menu

Press Digit Select
Key

Press Value Select
Key

Coordinates of 2 points scaling method if selected under

SEtuP

.

Lo_In1

.

Low signal
input 1.

000000 000000 000000
000000 000000 000000

Select digit to flash.

Select

-9

thru

9

for flashing first digit and

0

thru

9

for

other flashing digits. Move decimal point location
when flashing.

Lo_ rd1

Reading at
Lo In1.

000000 000000 000000
000000 000000 000000

Select digit to flash.

Select

-9

thru

9

for flashing first digit and

0

thru

9

for

other flashing digits. Decimal point is fixed by

dEC.Pt1

.

.

Hi_In1

.

High signal
input 1.

000000 000000 000000
000000 000000 000000

Select digit to flash.

Select

-9

thru

9

for flashing first digit and

0

thru

9

for

other flashing digits. Move decimal point location
when flashing.

.

Hi_rd1

.

Reading at
Hi In1.

000000 000000 000000
000000 000000 000000

Select digit to flash.

Select

-9

thru

9

for flashing first digit and

0

thru

9

for

other flashing digits. Decimal point is fixed by

dEC.Pt1

.

.

Lo_In2

.

Low signal
input 2.

000000 000000 000000
000000 000000 000000

Select digit to flash.

Select

-9

thru

9

for flashing first digit and

0

thru

9

for

other flashing digits. Move decimal point location
when flashing.

Lo_ rd2

Reading at
Lo In2.

000000 000000 000000
000000 000000 000000

Select digit to flash.

Select

-9

thru

9

for flashing first digit and

0

thru

9

for

other flashing digits. Decimal point is fixed by

dEC.Pt1

.

.

Hi_In2

.

High signal
input 1.

000000 000000 000000
000000 000000 000000

Select digit to flash.

Select

-9

thru

9

for flashing first digit and

0

thru

9

for

other flashing digits. Move decimal point location
when flashing.

.

Hi_rd2

.

Reading at
Hi In1.

000000 000000 000000
000000 000000 000000

Select digit to flash.

Select

-9

thru

9

for flashing first digit and

0

thru

9

for

other flashing digits. Decimal point is fixed by

dEC.Pt1

.

Preset function. Displayed for Total modes

A-b_Ud

. or

A_bU/d

PrESEt

Preset*

000000 000000 000000
000000 000000 000000

Select digit to flash.

Select

-9

thru

9

for flashing first digit and

0

thru

9

for

other flashing digits.

dEC.Pt1

is used. When the

meter counts up and reaches the Preset, it reverts to
Offset1. When the meter counts down and reaches
Offset1, it reverts to Preset. Set to 0 for no Preset.

Special curve offset for square root or custom curve linearization if selected under

ConFiG

.

rd0_In

.

000000 000000 000000
000000 000000 000000

Select digit to flash.

Select

-9

thru

9

for flashing first digit and

0

thru

9

for

other flashing digits. Decimal point is fixed by

dEC.Pt1

.