beautypg.com

Laurel Electronics LAUREATE SERIES 2 COUNTER-TIMER-SERIAL INPUT METER User Manual

Page 51

background image

51

KEYSTROKES FOR SETUP OF QUADRATURE RATE

If the MENU

key does not work, see Section 9 “Enabling & Locking Out Menu Items.”

Press
Menu

Press Digit
Select Key

Press Value Select
Key

Basic meter

_totAL

Quadrature total

_

InPut

Input

_quAdr

Quadrature

Extended

_rAtE_

Quadrature rate

_00000

Not applicable

0

Set to zero.

_00000

Leading zeros

0

Blank leading zeros.

1

Display leading zeros.

_00000

Scaling Method 1

0

Input scale factor 1 and offset 1

1

Use coordinates of 2 points method

_00000

Scaling Method 2 Make the same as Scaling Method 1

SEtuP

Setup

_00000

Operation of rear connec-
tor inputs 1 & 2.
True = logic 1 (0V or tied
to digital ground).
False = 0 (5V or open).

0

1 = Meter Reset*, 2 = Function Reset*

1

1 = Meter Reset*, 2 = Meter Hold*

2

1 = Meter Reset*, 2 = Peak or Valley Display*

3

1 = Meter Reset*, 2 = External Gate*

4

1 = Function Reset*, 2 = Meter Hold*

5

1 = Valley Only Display**, 2=Peak Only Display**

6

1 = Function Reset*, 2 = External Gate*

7

1 = Meter Hold**, Peak or Valley Display**

8

1 = Reset Total A**, 2 = Reset Total B**

9

1 = Force Alarm1, 2 = Force Alarm2

A

1 = Meter Reset*, 2 = Display Blank*

B

1 = Function Reset*, 2 = Display Blank*

C

1 = Meter Hold*, 2 = Display Blank*

D

1 = Peak or Valley Display**, 2 = Display Blank**

E

1 = Display Blank, 2 = External Gate*

F

1 = Display Item #2, 2 = Display Item #3

With 1 and 2 at 5V or open, Display Item #1.
-------------------------------------------------------------------

* 1 & 2 both at 0V = Meter Reset (can restore
totals).
** 1 & 2 both at 0V for selections

5

,

7

,

8

,

D

=

Function Reset* (erases all totals).

__0000

Display mode

0

Normal, overload to exponential format

1

Normal, overload to 999999

Normally select

1

, required for Preset function. See

dual signal conditioner for other available modes.

__0000

Counter mode

0

Basic counter

1

Extended counter (required for Quadrature Rate)

__0000

Not applicable

0

Set to 0.

ConFiG

Configura-
tion

__0000

Not applicable

0

Set to 0.