beautypg.com

Laurel Electronics LAUREATE SERIES 2 COUNTER-TIMER-SERIAL INPUT METER User Manual

Page 48

background image

48

E

1 = Display Blank, 2 = External Gate*

F

1 = Display Item #2, 2 = Display Item #3

With 1 and 2 at 5V or open, Display Item #1.
-------------------------------------------------------------------

* 1 & 2 both at 0V = Meter Reset (can restore
totals).
** 1 & 2 both at 0V for selections

5

,

7

,

8

,

D

=

Function Reset* (erases all totals).

__0000

Display mode

0

Normal, overload to exponential format

1

Normal, overload to 999999

Normally select

1

, required for Preset function. See

dual signal conditioner for other available modes.

__0000

Counter type

0

Basic counter (use for quadrature total)

1

Extended counter

__0000

Square root

0

Set to 0.

ConFiG

Configura-
tion

__0000

V-to-F batch

0

Set to 0.

____01

Response to

PEAK

pushbutton

0

Peak

1

Valley

2

Peak (1

st

push), Valley (2

nd

push)

dSPyno

Display

____01

Item #

1

Set to

1

(ignored for Quadrature Total).

PULSES

Zero index
pulses*

_00000 _00000 _00000
_00000 _00000

Select digit to flash.

Select

0

thru

9

for flashing digit to set zero index

pulses. This should pulses per revolution x edges
per pulse (1, 2 or 4) x scale factor.

GAtE_t

Gate time*

_000.00 _000.00 _000.00
_000.00 _000.00

Select digit to flash.

Select

0

thru

9

for flashing digit to set the display

update rate from 10 ms to 199.99 s.

dEC.Pt1

Decimal pt1

1

.

11111

Decimal point flashes.

1

.

11111

11

.

1111

111

.

111

1111

.

11

11111

.

1

111111

.

Press to shift decimal point.

Scale and Offset scaling method if selected under

SEtuP

SCALE1

Scale
Factor 1

0.00000 0.00000 0.00000
0.00000 0.00000 0.00000

Select the digit to flash
for the Scale Value, then
press one more time
for the Scale Multiplier.

Select

-9

thru

9

for flashing first digit and

0

thru

9

for

other flashing digits. This will set the Scale Value*
from -9.99999 to 9.99999 with a fixed decimal point.
Then press to select a value from

0.00001

to

100000

in decade steps for the Scale Multiplier.

Scale Factor = Scale Value x Scale Multiplier.

OFFSt1

.

Offset 1

000000 000000 000000
000000 000000 000000

Select digit to flash.

Select

-9

thru

9

for flashing first digit and

0

thru

9

for

other flashing digits.

dEC.Pt1

is used for decimal

point.