beautypg.com

Laurel Electronics LAUREATE SERIES 2 COUNTER-TIMER-SERIAL INPUT METER User Manual

Page 34

background image

34

KEYSTROKES FOR SETUP

If the MENU

key does not work, see Section 9 “Enabling & Locking Out Menu Items.”

Menus are dynamic. Menu items will only appear if appropriate for previously made menu
selections. For example, Batch menu items will only appear if “Batch” was selected under
“Rate.” Extended counter items will only appear if “Extended” was selected under “Config.”

Press
Menu

Press Digit
Select Key

Press Value Select
Key

A

_

OnLy

Rate for Channel A (Item #1).

B

a

s

ic

A_Atot

. Rate for Channel A (Item #1). Total for

Channel A (Item #2).

_bAtCH

Batch control mode. Batch total (Item #1).

Grand total or number of batches (Item #2). Fill rate
(Item #3).

_

InPut

Input

VF0-10

0-10V full-scale input

VF4-20

4-20 mA full-scale
input

VF_0-1

0-1 mA full-scale input

E

x

te

n

d

e

d

__1/A_

. 1/Rate for Channel A (Item #1).

SEtuP

Setup

_000_0

Stored totals

0

Zero totals at power-on.

1

Restore totals at power-on.

_000_0

Leading zeros

0

Blank leading zeros.

1

Display leading zeros.

_000_0

Scale factor 1 setup

0

Input scale factor 1 and offset 1.

1

Use coordinates of 2 points method.

_000_0

Operation of rear connec-
tor inputs 1 & 2.
True = logic 1 (0V or tied
to digital ground).
False = 0 (5V or open).

0

1 = Meter Reset*, 2 = Function Reset*

1

1 = Meter Reset*, 2 = Meter Hold*

2

1 = Meter Reset*, 2 = Peak or Valley Display*

3

1 = Meter Reset*, 2 = External Gate*

4

1 = Function Reset*, 2 = Meter Hold*

5

1 = Valley Only Display**, 2=Peak Only Display**

6

1 = Function Reset*, 2 = External Gate*

7

1 = Meter Hold**, Peak or Valley Display**

8

1 = Reset Total A**, 2 = Reset Total B**

9

1 = Force Alarm1, 2 = Force Alarm2

A

1 = Meter Reset*, 2 = Display Blank*

B

1 = Function Reset*, 2 = Display Blank*

C

1 = Meter Hold*, 2 = Display Blank*

D

1 = Peak or Valley Display**, 2 = Display Blank**

E

1 = Display Blank, 2 = External Gate*

F

1 = Display Item #2, 2 = Display Item #3

With 1 and 2 at 5V or open, Display Item #1.
-------------------------------------------------------------------

* 1 & 2 both at 0V = Meter Reset (can restore
totals).
** 1 & 2 both at 0V for selections

5

,

7

,

8

,

D

=

Function Reset* (erases all totals).