CTI Products RCD Advanced Client-Server User Manual
Page 50

MCNConfig Program: Network Interface Window
50
68-11824-210
Gateway
If the MCN Server PC will be using an IP address that is in a different subnet than the HIB-IP,
you must enter a Gateway IP address. This is the IP address of the IP router that the HIB-IP
will communicate to in order to talk to a PC that is on a different IP subnet. The Gateway IP
address must be on the same subnet as the HIB-IP unit.
If the MCN Server PC and the HIB-IP are on the same subnet, you do not have to enter a
Gateway address.
See details in the HIB-IP Hardware Reference Manual.
Group
MCN Group address for the HIB-IP.
Value: 00-FE Hex
See Warning in Important: MCN Address Setting on Page 26.
Module
MCN Module address for PCLTAs and HIB-IP units.
Value: 00-7E Hex
Usually a HIB-IP will be set for a module number of 10 hex
or above. This leaves room for HIB-232 modules in the system, which are limited to
Module Numbers 0-F.
See Warning in Important: MCN Address Setting on Page 26.
HIB-IP Authorized PCs
For system security purposes, the HIB-IP will communicate only with Authorized PCs Authorized
Servers). You may enter multiple IP addresses for Authorized PCs.
To add an Authorized PC, Right-Click on the Authorized PCs list to bring up the menu.
Select Append New.
Right-Click here to add
an Authorized PC.